Copy file name to clipboardExpand all lines: SUPPORT.md
+1-1Lines changed: 1 addition & 1 deletion
Display the source diff
Display the rich diff
Original file line number
Diff line number
Diff line change
@@ -12,7 +12,7 @@ Useful details include the Studio release, Windows version, ESP32-P4 firmware bu
12
12
13
13
**Can't find the board?** Check the USB data cable and serial device selection; use **Configuration → Firmware** to verify the ESP32-P4 and install matching firmware.
14
14
15
-
**Can't see SV in Wireshark?**Verify the isolated Ethernet topology, selected capture interface and whether a switch mirror/TAP is needed.
15
+
**SMV missing in ARSAS, DigSubAnalyzer or Wireshark?**Follow the [independent Ethernet receiver check](docs/INTEROP_FIRST_PACKET.md): verify SV RUNNING, capture on the actual NIC, and compare priority-tagged VLAN 0 with the optional untagged lab SCL.
16
16
17
17
**Interested in IEC 61850 subscriber testing?** Share results in the [community interoperability guide](docs/COMMUNITY_TESTING.md).
Use this when ARStack Studio reports SV publishing but ARSAS or DigSubAnalyzer shows no Sampled Values. The goal is to identify whether the frame is **missing from the receiving Ethernet interface** or **arriving but not being decoded**.
4
+
5
+
## 1. Confirm SV is actually publishing
6
+
7
+
Connect the ESP32-P4 to an **isolated laboratory Ethernet network**. Open ARStack Studio and confirm **SV RUNNING** with increasing transmit/frame counts. PTP RUNNING alone does not mean SV frames are being transmitted.
8
+
9
+
## 2. Capture on the receiver's Ethernet adapter
10
+
11
+
On the same Windows machine used for the analyzer:
12
+
13
+
1. Select the **physical Ethernet adapter** connected to the ESP32-P4 laboratory network, rather than Wi-Fi or the Npcap loopback adapter.
14
+
2. In Wireshark, start a new capture **with no capture filter**. A capture filter is different from a display filter.
15
+
3. While Studio is publishing, apply the **display filter**`eth.type == 0x88ba || vlan.etype == 0x88ba`. This covers both plain SV Ethernet frames and SV inside an 802.1Q priority/VLAN tag. The outer `eth.type` may be `0x8100` for tagged frames, so `eth.type == 0x88ba`**alone is not sufficient**.
16
+
4. Record whether SV frames appear and whether packet details show `APPID`, `svID`, `smpCnt`, destination MAC and, where present, VLAN ID/PCP. Check the actual packet bytes, not only the configured SCL; NIC VLAN offload/stripping can change what a host capture exposes.
17
+
5. Save **3–5 seconds** of traffic as `.pcapng` or `.pcap` with **no capture filter**, along with the selected NIC name, physical topology, Studio/firmware versions, analyzer versions and chosen stream filters. Remove confidential project information before sharing.
18
+
19
+
The reference M3.H profile uses APPID `0x4000`, destination `01:0C:CD:04:00:01` and approximately **4,000 frames/s**. The stream ID depends on the profile deployed by Studio; do not assume a specific `svID` without examining the wire.
20
+
21
+
## 3. Compare VLAN-tagged with untagged laboratory SV
22
+
23
+
The included **reference SCL** requests Ethernet **802.1Q priority tagging**: VLAN ID `0`, PCP `4`. Some PC network or switch paths handle priority-tagged traffic differently.
24
+
25
+
For diagnosis only, an alternative [untagged 4I+4V SCL](../apps/arstack_studio/templates/arstack_4i4v_untagged_lab.scd) keeps the same APPID, multicast MAC, data-set and sample rate **but omits VLAN tagging**. In Studio, stop publishing, load this SCL, select/deploy its SV stream and restart. Compare the receiving capture against the original configuration.
26
+
27
+
**Do not change the VLAN scheme on an operating substation network.** This is an isolated-bench comparison to identify an Ethernet capture path difference; a change in receive behavior is evidence about the path, not proof of an arbitrary SV protocol fault.
28
+
29
+
## 4. Interpret the result
30
+
31
+
| What the receiver PC observes | Next engineering action |
32
+
| --- | --- |
33
+
| No plain or VLAN-encapsulated SV frames on the selected adapter | Check board link, Studio TX state, adapter choice, switch mirror/TAP, NIC VLAN offload and tagged VLAN forwarding. First confirm the combined display filter was used. |
34
+
| SV appears in Wireshark but not in DigSubAnalyzer | Note raw frame and decoder counters and share the capture; inspect Npcap filter and raw BER path. |
35
+
| SV appears in Wireshark but ARSAS snapshot stays empty | Use ARSAS's **First received SV stream** option (when available), or match selected SCL APPID/MAC/`svID` to the actual packet. |
36
+
| SV decodes in both applications | Compare samples, `smpCnt` rollover and waveform plausibility, then continue to timing/interoperability checks. |
37
+
38
+
Open [P0 receiver acceptance issue #324](https://github.com/masarray/arstack61850/issues/324) for incident tracking. A self-decoded PCAP from Studio cannot replace an **independent RX capture from the affected NIC**.
0 commit comments