Add multicam image registration backend#1750
Draft
romleiaj wants to merge 10 commits into
Draft
Conversation
homography.ts: 3x3 matrix primitives (multiply, invert, apply, linear and DLT solvers) plus warp-grid subdivision helpers. transform.ts: keypointgui-style transform models (translation / rigid / similarity / affine / homography) that all estimate to a plain Matrix3, with Similarity as the single shared default. CameraCalibrationStore: the persistence core for camera-rig calibration -- per-pair homographies, correspondences, transform types, and producer provenance, with hydrate() from dataset meta, dirty tracking, and the portable calibration.json round trip (toCalibrationJson / loadCalibrationText). Interactive creation (point picking, fitting, overlay preview) is not part of this branch; it layers on top in the Manual Alignment GUI. Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
Persist cameraHomographies / cameraCorrespondences / cameraTransformTypes / cameraCalibrationSource in dataset meta on both platforms (server allowlist + desktop meta merge), and load calibrations produced externally (e.g. by kamera) at import time: the multicam import dialog gains a per-camera transform-file picker, the desktop backend parses DIVE calibration .json pairs (fromCalibrationPairs / toCalibrationPairs) and auto-discovers a calibration.json in the import parent folder, and saveMetadata writes the portable calibration.json alongside the project so the calibration travels with the dataset. Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
When every camera resolves a transform into the reference camera's space (first camera in display order, composed through the calibration pair graph), an Align button warps each pane's imagery and annotations into that shared space at draw time -- stored geometry always stays native per camera. Includes: AlignedViewStore + resolution wiring in the Viewer; AlignedImageLayer (sub-quad warped imagery with seam overlap); display-transform routing through every annotation layer; transform-aware linked pan/zoom (useAlignedNavigation/useLinkedViewers, with the raw screen-delta camera sync retired once transforms exist); drawing/editing on any camera with edits mapped back through the inverse; and a continuous cross-camera mirror that re-projects every geometry edit onto all other calibrated cameras. Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
Importing single-camera annotations into a calibrated multicam dataset now offers an "Import to all cameras" checkbox: after the import lands on the active camera, every track is copied onto each other camera through the camera-to-camera homographies (bounds, rotated bounds, and GeoJSON geometry), then saved. Unlike the Align View continuous mirror this is a data import, so confidence pairs and track/feature attributes are copied too. Gated on the whole rig resolving to the reference (alignedView.available), independent of the display toggle. Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
The dataset's saved calibration moves from a single all-pairs
calibration.json to one calibration_<camera>.json per non-reference
camera (a pair not touching the reference files under its right
camera), matching the per-camera files users already handle from
kamera. File names are discovery/provenance only: the pair's left/right
names inside each file body stay authoritative, so a misnamed or copied
file can never rebind a transform to the wrong camera. The legacy
single file is still read and is migrated (rewritten per-camera, then
removed) on the next save; stale per-camera files are cleaned up so the
on-disk set always mirrors the saved calibration.
Per-file producer stamps are compared when the set is merged (project
load and import seeding): agreement keeps the stamp, disagreement
becomes a { mixed: true, files: {...} } composite that the Align View
tooltip surfaces as a mixed-generation warning instead of composing
silently. A save never writes the composite into per-camera files --
that would read back as a unanimous rig.
Parent-folder transform discovery now returns every self-identified
calibration file (calibration.json first, then per-camera files), and
the multicam import dialog auto-attaches calibration_<camera>.json to
its matching camera slot. Files written by DIVE now also self-identify
with type: dive-camera-calibration so discovery recognizes them.
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
The per-camera calibration_<camera>.json files are now the only on-disk form: the single all-pairs calibration.json is no longer read, migrated, or given priority during import discovery. The Export menu gains explicit calibration export -- one file per calibrated camera, or all of them zipped -- built from the same per-camera grouping the save path uses, and the multicam Everything zip now carries the files too. Exports resolve the calibration the same way loading does (standalone files first, the import-time meta seed otherwise) and never stamp a file with a mixed composite source. Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
Calibration export is now strictly per-camera -- one calibration_<camera>.json at a time, no all-cameras zip -- and works on both platforms: desktop writes through the backend as before, web builds the file client-side from the dataset meta and downloads it. The Import menu gains a matching per-dataset calibration import (same workflow as annotation import): pairs the file names replace the current ones, other cameras' pairs are kept, so per-camera files can be imported one at a time to assemble a rig; the viewer store rehydrates immediately so the Align View picks up the new transforms without a reload. Grouping and merge semantics live in a new shared vue-media-annotator module used by the desktop backend, both Export menus, and both import paths, so listed cameras, written files, and merge behavior cannot drift between platforms. Web needs no server changes: the calibration meta fields were already allowlisted. Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
The Import and Export buttons now advertise "Supplementary Data" in their hover tooltips instead of "Annotation Data", since both menus carry calibrations as well. The Import Calibration blurb shrinks to one line. The warp-on-import checkbox moves out of the active-camera alert to sit beside Overwrite as "Warp to All", always visible on multicam datasets and greyed out until the whole rig resolves, with an "N/M cameras calibrated" hint. The viewer publishes that count into AlignedViewStore from the same computation as the Align View tooltip, so the two indicators can never disagree. Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
The generic Import Calibration button becomes one button per
non-reference camera pair ("Import eo -> ir"), each scoped to its
camera: only the file's pairs naming that camera are taken, they
replace that camera's current pairs, and other cameras' pairs are
kept -- so per-camera files assemble a rig one at a time and a
multi-pair file pointed at one camera doesn't drag the rest along.
Scoping to a camera the file doesn't name refuses with a clear error.
Buttons are green when the camera already has a calibration and yellow
when it doesn't, and importing onto an existing one asks for
confirmation before replacing it, so no separate overwrite toggle is
needed. The camera filtering and pair/camera summary live in the
shared calibration-file module so desktop and web behave identically.
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
…ormat
"Calibration" collided with the pre-existing stereo camera file (an
intrinsic/extrinsic camera model for the measurement pipeline), and in
computer vision this process is image registration, so the feature says
registration everywhere: "Import Registration" / "Registration: <camera>"
menu sections, importCameraRegistration and exportCameraRegistration API
members and IPC channels, registrationProgress ("N/M cameras registered")
published on the aligned-view store, matching error messages, the
internals (CameraRegistrationStore, cameraRegistrationFiles, and the
load/merge/build helpers), and the wire format: the dataset meta field is
cameraRegistrationSource, renamed through the server models, allowlist,
and tests alongside the RegistrationSource type and stamp helpers. Files
are named <camera>_to_<reference>_registration.json and self-identify as
dive-camera-registration: each file states the destination of the mapping
it carries (ir_to_eo_registration.json registers ir onto eo), making the
reference-camera rule -- first camera in display order -- legible from
the artifacts themselves. The name scheme contains neither "calibration"
nor "cal", so these files can no longer be mis-suggested as stereo camera
files by the stereo parent-folder discovery heuristic. The Align View
keeps its name (registration is the data and process; the Align View is
the display mode that renders registered imagery), and the stereo
camera-file surfaces are untouched.
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
No description provided.