Skip to content

About

Server motherboard hardware monitoring

Topics

Resources

Stars

1 star

Watchers

1 watching

Forks

Repository files navigation

hardware-events

Build

A small daemon that keeps a home server quiet and cool: it reads temperature sensors, drives the fans through ipmitool (or any other command), spins down idle hard drives, and exposes everything to Prometheus or Zabbix.

The project started when I changed the fans on a Supermicro motherboard and they started to run at full speed, because their nominal speed was measured too low for the BMC. I could have bought other fans, but I didn't want to. I have it running on various Supermicro server boards (X9/X10/X11) and manage the different fan zones separately.

Features

  • Reads temperatures from sysfs files or from the output of any command (CPU, chipset, SATA and NVMe drives, smartctl, ...).
  • Controls fan speed per zone with linear rules (temperature range → fan speed range), with a moving average to avoid oscillation.
  • Several sensors can drive the same zone: the zone always runs at the highest speed requested by any of its sensors.
  • Hands fan control back to the motherboard when the daemon stops.
  • Monitors disk activity from /proc/diskstats and puts idle drives in standby, while still reporting their temperature when they are awake.
  • Exposes disk_temperature, disk_active and fan_speed as Prometheus metrics.
  • Runs scheduled tasks fed by Go templates, for example zabbix_sender.
  • Integrates with systemd (Type=notify and watchdog).
  • Simulation mode to test your rules without touching the hardware.

Requirements

  • Linux. FreeBSD binaries are built but not tested, and you will need to adapt the sensor paths since the defaults rely on Linux sysfs.
  • Root privileges (or equivalent) to run ipmitool, hdparm and read some sensors.
  • The command line tools you reference in the configuration, typically ipmitool, hdparm and optionally smartctl.
  • For drive temperatures via /sys/block/*/device/hwmon, a kernel with the drivetemp module (5.6+).

Installation

Packages

Each release provides .deb, .rpm and .apk packages for amd64, 386, arm (v6/v7) and arm64, plus tar.gz archives for Linux and FreeBSD.

The packages install:

Path Purpose
/opt/hardware-events/hardware-events binary
/opt/hardware-events/config.yaml configuration (kept on upgrade)
/opt/hardware-events/zabbix_template.go.txt Zabbix template (kept on upgrade)
/etc/systemd/system/hardware-events.service systemd unit

The post-install script enables and starts the service. Edit config.yaml for your hardware, then systemctl restart hardware-events.

From source

git clone https://github.com/creativeprojects/hardware-events.git
cd hardware-events
make build          # builds ./hardware-events
make test           # runs the test suite

make deploy copies the binary, config-local.yaml, the templates and the unit file to /opt/hardware-events/. make deploy-<host> does the same over rsync using config-<host>.yaml.

Running

hardware-events [-c config.yaml] [-q | -v | -d] [-s [-r1 seed] [-r2 seed]]
Flag Description
-c configuration file (default config.yaml)
-q quiet: only warnings and errors
-v verbose: debug output
-d debug: trace output, including every sensor reading
-s simulation mode (see below)
-r1, -r2 random seeds used in simulation mode (default 42)

A relative configuration path is resolved from the directory of the binary, not from the current directory. The same applies to template source paths.

The daemon runs until it receives SIGINT or SIGTERM. On shutdown it runs the fan exit_command so the motherboard takes control of the fans again.

systemd

The provided unit uses Type=notify with a 15 minute watchdog. The daemon notifies systemd when it is ready, when it is stopping, and pings the watchdog periodically.

systemctl enable --now hardware-events
journalctl -u hardware-events -f

How fan control works

Each fan zone (for example CPU fans and chassis fans) has an ID understood by your set_command and a list of sensors to watch. Each sensor has a list of rules:

  1. On every tick (run_every), the sensor temperature is read and added to a moving average covering the average duration.
  2. The first rule whose temperature range contains the averaged value is applied. The fan speed is interpolated linearly between fan_speed.from at temperature.from and fan_speed.to at temperature.to. Alternatively, a rule can request a fixed speed with fan_speed.set.
  3. If no rule matches, the sensor requests the zone min_speed when below all the rules, or max_speed when above.
  4. A rule can carry its own run_every to read the sensor more often while that rule is active. The default interval is restored when the rule no longer matches.
  5. The zone collects the speed requested by each of its sensors and sets the fan to the highest one, clamped between min_speed and max_speed. The command is only run when the speed changes.

Configuration

The configuration is a single YAML file. A complete example is in config.yaml; the sections below describe each key.

Commands are run through /bin/sh -c. Some placeholders are expanded before running a command or opening a file:

Placeholder Available in Value
${DEVICE} disk sensors, disk_power_status resolved device path, e.g. /dev/sda
${DEVICE_NAME} disk sensors, disk_power_status kernel device name, e.g. sda
${FAN_ZONE} fan_control.set_command zone id
${FAN_SPEED} fan_control.set_command speed in percent

sensors

Named sources of integer temperature readings. A sensor is one of:

sensors:
  # run a command and extract the value with a regular expression (first capture group)
  smartctl:
    command: "/usr/sbin/smartctl -l scttempsts ${DEVICE}"
    regexp: "Current Temperature:\\s+(\\d+) Celsius"
    timeout: 5s

  # read a single file; globs are allowed but must match exactly one file
  cpu:
    file: "/sys/devices/platform/coretemp.0/hwmon/hwmon*/temp1_input"
    divider: 1000

  # read several files and average the values
  cpu-average:
    files:
    - "/sys/devices/platform/coretemp.0/hwmon/hwmon*/temp?_input"
    divider: 1000

  pch:
    file: "/sys/class/thermal/thermal_zone1/temp"
    divider: 1000

  satatemp:
    file: "/sys/block/${DEVICE_NAME}/device/hwmon/hwmon*/temp1_input"
    divider: 1000

  nvmetemp:
    file: "/sys/block/${DEVICE_NAME}/device/hwmon*/temp1_input"
    divider: 1000
Key Description
command command to run; its standard output is the value unless regexp is set
regexp regular expression applied to the command output; the first capture group is the value
file path or glob of a file containing the value
files list of paths or globs; all matching values are averaged
divider divide the raw value (sysfs reports millidegrees, so use 1000)
timeout maximum duration for command

Sensors that use ${DEVICE} or ${DEVICE_NAME} are meant to be referenced by a disk (see disks), which provides the device.

fan_control

fan_control:
  init_command: "/usr/bin/ipmitool raw 0x30 0x45 0x01 0x01"   # set fan mode to full
  set_command: "/usr/bin/ipmitool raw 0x30 0x70 0x66 0x01 ${FAN_ZONE} ${FAN_SPEED}"
  exit_command: "/usr/bin/ipmitool raw 0x30 0x45 0x01 0x00"   # set fan mode back to normal
  timeout: 5s
  parameters:
    FAN_ZONE:
      format: "%#x"     # ipmitool wants hexadecimal
    FAN_SPEED:
      format: "%#x"
  zones:
    zone1:
      id: 0
      min_speed: 25
      sensors:
        cpu:
          average: 30s
          run_every: 10s
          rules:
          - temperature:
              from: 40
              to: 60
            run_every: 5s
            fan_speed:
              from: 25
              to: 100
    zone2:
      id: 1
      min_speed: 25
      run_every: 5m
      sensors:
        datapool1:
          average: 5m
          rules:
          - temperature:
              from: 40
              to: 60
            fan_speed:
              from: 30
              to: 100
Key Description
init_command run once at startup, typically to take manual control of the fans (optional)
set_command run each time a zone speed changes; use ${FAN_ZONE} and ${FAN_SPEED}
exit_command run at shutdown to give control back to the motherboard (optional)
timeout maximum duration for each command
parameters.<NAME>.format fmt format applied to a placeholder before expansion (default %d)

Zone keys:

Key Description
id zone identifier passed as ${FAN_ZONE}
min_speed lowest speed ever set, in percent (default 25)
max_speed highest speed ever set (default 100)
run_every default read interval for the sensors of this zone
sensors map of sensor name → sensor settings. The name is either a key of sensors or a key of disks

Sensor keys inside a zone:

Key Description
average length of the moving average window. Must be at least run_every
run_every read interval, overrides the zone value
rules list of rules, see below

Rule keys:

Key Description
temperature.from, temperature.to temperature range the rule applies to, in °C
fan_speed.from, fan_speed.to speed at temperature.from and temperature.to, interpolated in between
fan_speed.set fixed speed for the whole range, instead of from/to
run_every read interval while this rule is active (optional)

disk_power_status

Named methods to check whether a drive is spinning and to put it in standby. The check output is matched against the active, standby and sleeping strings.

disk_power_status:
  hdparm:
    check_command: "/sbin/hdparm -C ${DEVICE}"
    active: "active/idle"
    standby: "standby"
    sleeping: "sleeping"
    standby_command: "/sbin/hdparm -y ${DEVICE}"
    timeout: 5s

file can be used instead of check_command to read the status from a sysfs file. When a single method is defined, every disk uses it; otherwise set power_status on each disk.

disks

disks:
  rpool1:
    device: "/dev/disk/by-id/ata-SAMSUNG_SSD_first"
    temperature_sensor: satatemp
    monitor_temperature: always
  datapool1:
    device: "/dev/disk/by-id/ata-ST2000DM001-first"
    temperature_sensor: satatemp
    monitor_temperature: when_active
    last_active: 50m
    standby_after: 1h
Key Description
device device path. Symlinks such as /dev/disk/by-id/... are resolved to the kernel device
temperature_sensor name of a sensor from sensors to read this disk temperature
monitor_temperature always, when_active (only when spinning and not idle, so a sleeping drive is never woken up) or never
last_active how long without I/O before the disk is considered idle (default 1m)
standby_after put the disk in standby after this much time without I/O. Leave unset to never force standby
check_every how often the standby watch checks the disk (default 5m, with ±1 minute jitter)
power_status name of a disk_power_status method, needed when more than one is defined

Disk activity comes from /proc/diskstats (read and write sectors on the disk partitions). Disk status and temperature readings are cached for one minute.

disk_pools

Groups disks by name, for reporting only. The pool name is attached to the disk metrics and the Zabbix template reports the number of active disks per pool.

disk_pools:
  rpool:
    - rpool1
    - rpool2
  datapool:
    - datapool1
    - datapool2

templates, tasks and schedule

Tasks run a command, optionally with a rendered Go template on its standard input. Schedules decide when a task runs: startup and/or every <duration>.

templates:
  zabbix:
    source: "zabbix_template.go.txt"   # relative to the binary

tasks:
  zabbix_sender:
    command: "zabbix_sender -z 127.0.0.1 -s \"Zabbix server\" -i -"
    timeout: 5s
    stdin:
      template: zabbix

schedule:
  zabbix:
    task: zabbix_sender
    when:
    - startup
    - every 5m

The template receives the whole runtime state. The most useful fields are .Disks (with .Name, .Pool, .IsActive, .HasTemperature, .TemperatureAvailable, .Temperature) and .DiskPools (with .Name, .CountActive). See zabbix_template.go.txt for an example.

telemetry

telemetry:
  prometheus:
    enabled: true
    listen_address: ":8080"

When enabled, metrics are served at http://<listen_address>/metrics.

Prometheus metrics

Metric Labels Description
disk_temperature name, device, pool disk temperature in °C, only reported when the temperature is available
disk_active name, device, pool 1 when the disk is spinning, 0 otherwise. pool is only set for disks that belong to a pool
fan_speed name, id current zone fan speed in percent

Zabbix

The bundled template feeds zabbix_sender with:

  • disk.pools and disk.names: JSON arrays for low-level discovery ({#POOL_NAME}, {#DISK_NAME})
  • disks.active[<pool>]: number of active disks in the pool
  • disks.temperature[<disk>]: disk temperature, or 0 when the disk is in standby

Simulation mode

Start with -s (or set simulation: true in the configuration) to try a configuration on a machine without the hardware. Sensors return random temperatures driven by the -r1/-r2 seeds, disks start active and go to standby when asked, and every command is logged instead of being run. Use -d to see the readings and the resulting fan speeds.

hardware-events -s -d -c config.yaml

External resources

License

GPL v3

About

Server motherboard hardware monitoring

Topics

Resources