Skip to content
Merged
Show file tree
Hide file tree
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
Original file line number Diff line number Diff line change
Expand Up @@ -130,6 +130,11 @@ transformer on an image. Each adapter model may be used only once per generation
re-identify it in the Model Manager.
A control layer from an older project may still be set to **ControlNet**, which Anima cannot run; its
settings say so and offer **Switch to Anima ControlNet-LLLite**, which keeps the selected adapter.
- **When inpainting or outpainting on the canvas**, pick the Inpainting adapter as the optional **Inpaint
Adapter** in the Generate panel's **Components** section, and set its **Inpaint adapter weight** (1 by
default). Invoke then conditions the adapter on the raster image and the region being generated; the
setting is ignored for text-to-image and image-to-image. The adapter and its weight are recorded in the
image's metadata and restored by **Recall All** and **Remix Image**.
- **In the workflow editor**, add an **Anima ControlNet-LLLite** node, give it the conditioning image and
a control model, and connect it to the **Control LLLite** input of **Denoise - Anima**, collecting
several nodes to combine them.
Expand Down
Original file line number Diff line number Diff line change
Expand Up @@ -123,7 +123,7 @@ Adjustment child rows each have their own settings, such as **Brightness** and *
### Control layer

* **Adapter type** — ControlNet, T2I Adapter, Control LoRA, Z-Image ControlNet or Anima ControlNet-LLLite, depending on the model selected in the Generate panel.
* **Model** — the installed control models of that type for the same model family. If the list is empty, install one from the starter models. For Anima, the list holds the LLLite control adapters but not the Inpainting adapter, and each LLLite model can drive only one control layer per generation.
* **Model** — the installed control models of that type for the same model family. If the list is empty, install one from the starter models. For Anima, the list holds the LLLite control adapters but not the Inpainting adapter, which is chosen as the **Inpaint Adapter** in the Generate panel's Components section instead, and each LLLite model can drive only one control layer per generation.
* **Weight** — how strongly the guide is followed (0 to 2; the default is 0.75 for ControlNet).
* **Step range** — the part of the generation, from start to finish, in which the guide applies.
* **Control mode** (ControlNet only) — **Balanced**, **More prompt**, **More control** or **Unbalanced**.
Expand Down
3 changes: 2 additions & 1 deletion invokeai/frontend/webv2/public/locales/en.json
Original file line number Diff line number Diff line change
Expand Up @@ -2668,7 +2668,8 @@
"pidSteps": "PiD steps",
"pidHelp": "Replaces the VAE decode with a 4x super-resolution decode.",
"pidFitHelp": "Generates at the requested size, then decodes 4x and scales back down.",
"pidNativeHelp": "The requested size is the 4x target; generation runs at a quarter of it."
"pidNativeHelp": "The requested size is the 4x target; generation runs at a quarter of it.",
"animaInpaintAdapterWeight": "Inpaint adapter weight"
},
"upscale": {
"concepts": "Concepts",
Expand Down
Loading
Loading