Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
Summary
Adds automatic detection of empty chemical canisters (10–15L liquid chlorine and acid) based on dosing pump duty-cycle trends observed across discontinuous filtration cycles.
Key Changes
CanisterMonitor):min_delta_p = 0.07), detecting depletions rapidly while avoiding false positives.0) on canister refill as soon as duty cycle recovers./status/disinfection/{ph,cl}/canister_empty.device_class: problem) inhome-assistant/mqtt.yamlfor both canisters (ready for HA automations).canister_cycles = 3inconfig.iniunder[disinfection].Verification
uv run pytest).uv run ruff check .anduv run ty checkboth pass with 0 errors.history.csv, 559 cycles): Accurately detects empty canister events (including October 19–24 runout within ~13 hours) matching the pool owner's ~6 annual canister changes.