A Windows desktop app for DM40-series multimeters and EL15 electronic loads over Bluetooth Low Energy. Tkinter front-end, a custom WinRT BLE transport, and zero third-party Python dependencies at runtime.
Tip
Prebuilt binaries are available on the Releases page.
Warning
Windows only. The transport layer talks to WinRT BLE GATT directly; there is no maintained Linux or macOS port.
- Features
- Device Support
- Requirements
- Run from Source
- Build for Release
- Keybinds
- Architecture
- Protocol Notes
- Notes
- License
- One binary, two device families: handlers are dispatched dynamically after the device is identified.
- Scrolling waveform with live value, pause/resume, click-to-pin, drag-to-select range with min / max / Δ.
- Raw packet inspector with inline CRC pass/fail tags and integrated find popup.
- One-shot CSV buffer export or continuous CSV recording.
- 17 built-in themes with a live preview browser; selection is persisted across sessions.
- Release build is tuned for small size: Nuitka one-file + size-oriented MSVC flags + aggressive stdlib pruning.
| Device | Status | UI / Telemetry | Controls |
|---|---|---|---|
| DM40 series | Supported | Live reading, waveform, raw packet view, stats | Hold, auto, relative, range and mode switching |
| EL15 | Experimental | Voltage / current / power, waveform, raw packet view, stats | Load on/off, CC / CV / CR / CP / CAP / DCR mode switching, setpoint entry |
- Large primary reading with auxiliary values.
- Mode, range, battery, charging, lock, and hold state rendering.
- Hold, auto-range, relative, capacitance, diode / continuity, frequency, and temperature controls.
- Roughly matches
atk-xtoolfeature coverage for day-to-day meter use.
- Dedicated voltage, current, and power readout cells.
- Runtime, temperature, fan speed, mode, load state, and setpoint display.
- CC, CV, CR, CP, CAP (battery capacity), and DCR (DC resistance) mode switching from the main control bar.
- CAP mode shows accumulated energy (Wh) and capacity (Ah) in place of the setpoint.
- DCR mode shows the I1 / I2 test currents and the measured milliohm resistance.
- Device-only modes (
POW [A],POW [DT],ADV [L],ADV [S]) surface as a single disabled radio that tracks the active mode; the setpoint entry is disabled in these modes. - Load control and editable setpoint command entry.
- Windows 10 version 1703 (Creators Update, build 15063) or newer. The BLE GATT APIs this app relies on (
IBluetoothLEDevice3,IGattDeviceService3) were introduced in that release;IBluetoothLEDevice6connection tuning is used when available and skipped otherwise. - Python 3.13+ with Tkinter (source runtime only).
- MSVC Build Tools compatible with Nuitka
--msvc=latest(release build only).
Note
Other Python versions may work, but are currently untested.
py -3.13 main.pyNo extra package install is required for source execution.
Install the build dependency:
py -3.13 -m pip install --upgrade nuitkaThen run:
build_release.cmdThe release path is intentionally size-focused:
- one-file Nuitka build
- size-oriented compiler and linker flags
- precompiled minimal
ctypesshim for frozen builds - aggressive exclusion of unused stdlib modules and Tcl/Tk payloads
- optional module-closure reports for auditing import growth
The build script is CI-friendly:
- deterministic compiler and linker environment setup
- non-zero exit on failure
- configurable via
DM40_*environment variables
Build environment variables:
| Variable | Purpose |
|---|---|
DM40_PYTHON |
Python launcher or command (default: py -3.13) |
DM40_OUT_DIR |
Build output directory |
DM40_CCFLAGS |
Additional compiler flags |
DM40_LINKFLAGS |
Additional linker flags |
DM40_NUITKA_FLAGS |
Additional Nuitka flags |
DM40_MODE_FLAGS |
Build mode flags (default: --deployment) |
DM40_CONSOLE_MODE |
Nuitka console mode (disable, attach, force) |
DM40_MSVC |
Nuitka MSVC selector (default: latest) |
DM40_JOBS |
Parallel compile jobs |
DM40_EMIT_MODULE_REPORTS |
Emit modules.txt and XML report (1 local default, 0 when CI is set) |
Minimal CI example:
set DM40_PYTHON=py -3.13
set DM40_OUT_DIR=build\ci\nuitka
call build_release.cmd| Scope | Keybind | Action |
|---|---|---|
| Global | P |
Pause or resume waveform updates |
| Global | R |
Start or stop waveform CSV recording |
| Global | Ctrl+S |
Save the current waveform buffer to CSV |
| Global | Ctrl+C |
Copy the current reading text |
| Raw packet view | Ctrl+F |
Open the find popup |
| Raw packet view | Enter / F3 |
Next match |
| Raw packet view | Shift+Enter / Shift+F3 |
Previous match |
| Raw packet view | Esc |
Close the find popup or clear its focus |
| Waveform | Left click on trace | Pin a tooltip at a sample |
| Waveform | Left-click drag | Select a range and show min / max / Δ |
| Waveform | Right click | Clear the pinned point or current selection |
| Path | Description |
|---|---|
main.py |
Entry point; installs frozen-build shims before launching the app |
shared/base_app.py |
Single-window Tk app, scan/connect flow, waveform view, and handler selection |
shared/ble_worker.py |
Shared BLE worker plus device-family probe |
shared/device_registry.py |
Single-source registry of supported device handlers |
shared/nanowinbt/ |
Custom Windows BLE and WinRT transport layer |
shared/mini_asyncio.py |
Small async runtime used instead of full asyncio |
dm40/app.py |
DM40 handler, controls, and UI updates |
dm40/parsing.py |
DM40 packet parsing and meter-state decoding |
dm40/protocol_constants.py |
DM40 commands, flags, scale maps, and mode groups |
el15/app.py |
EL15 handler, controls, and UI updates |
el15/protocol_constants.py |
EL15 commands and status packet parsing |
GUI/ |
Shared widgets, controls, theming, and custom dialogs |
build_release.cmd |
One-file Nuitka build script |
Reverse-engineered from BLE HCI captures and device traffic inspection.
Both device families currently use the same BLE service and characteristic layout in the shared worker:
| Direction | UUID |
|---|---|
| Service | 0000fff0-0000-1000-8000-00805f9b34fb |
| Notify | 0000fff1-0000-1000-8000-00805f9b34fb |
| Write | 0000fff3-0000-1000-8000-00805f9b34fb |
DM40 command frames are 6 bytes:
AF 05 03 <cmd> <arg> <checksum>
Checksum formula:
(-sum(first_5_bytes)) & 0xFF
Common commands:
CMD_ID af 05 03 08 00 41
CMD_READ af 05 03 09 00 40
CMD_HOLD_ON af 05 03 04 01 01
CMD_HOLD_OFF af 05 03 04 01 00
CMD_AUTO_ON af 05 03 03 01 01
CMD_AUTO_OFF af 05 03 03 01 00
CMD_RELATIVE af 05 03 05 01 01
CMD_CAP af 05 03 06 01 03
CMD_DIODE af 05 03 06 01 04
CMD_CONT af 05 03 06 01 44
CMD_HZ af 05 03 06 01 05
CMD_TEMP af 05 03 06 01 45
DM40 notifications use two main packet families:
- Model ID: prefix
DF 05 03 08 14 - Measurement: prefix
DF 05 03 09
DM40 measurement decode summary:
| Byte(s) | Field |
|---|---|
data[5] |
Mode and range flag (FLAG_INFO) |
data[6] |
Status byte |
data[14:16] |
Primary counts (m1, little-endian) |
data[12:14] |
Secondary counts (m2, little-endian) |
data[10:12] |
Tertiary counts (m3, little-endian) |
data[-8] |
Scale and sign slot 1 |
data[-9] |
Scale and sign slot 2 |
data[-10] |
Scale and sign slot 3 |
CRC check:
(sum(all_bytes) & 0xFF) == 0
DM40 status byte (data[6]) summary:
| Bits | Meaning |
|---|---|
& 0x07 |
Battery level (0-5 bars) |
& 0x08 |
Charging |
& 0x40 |
Screen lock |
& 0x80 |
Hold |
EL15 status notifications use header:
DF 07 03 08
EL15 poll command:
AF 07 03 08 00 3F
Common EL15 commands:
CMD_LOAD_ON af 07 03 09 01 04
CMD_LOAD_OFF af 07 03 09 01 00
Mode switch commands share a common prefix AF 07 03 03 01 <mode>:
| Mode | ID | Command |
|---|---|---|
| CC | 0x01 |
af 07 03 03 01 01 |
| CAP | 0x02 |
af 07 03 03 01 02 |
| CV | 0x09 |
af 07 03 03 01 09 |
| DCR | 0x0A |
af 07 03 03 01 0a |
| CR | 0x11 |
af 07 03 03 01 11 |
| CP | 0x19 |
af 07 03 03 01 19 |
Device-only modes observed in status packets, cannot be set from the app
| Mode | ID | Label |
|---|---|---|
| Power dynamic test | 0x03 |
POW [DT] |
| Advanced list | 0x04 |
ADV [L] |
| Power (auto) | 0x0B |
POW [A] |
| Advanced scan | 0x0C |
ADV [S] |
Setpoint command layout:
AF 07 03 04 04 <float32 payload>
The EL15 parser treats valid status packets as 28-byte frames. The fixed fields are:
| Byte(s) | Field |
|---|---|
data[5] & 0x1F |
Mode ID (ready bit folded in for CC/CV/CR/CP) |
data[5] & 0x01 |
Ready / measuring flag (clear while in device menus) |
(data[5] >> 6) | ((data[6] & 0x01) << 2) |
Fan speed (0-5) |
data[6] & 0x02 |
Load on |
data[6] & 0x04 |
Panel lock |
data[7:11] |
Voltage (float32) |
data[11:15] |
Current (float32, unused in DCR/ADV/POW) |
Bytes [15:19], [19:23], [23:27] are mode-specific:
| Mode | [15:19] |
[19:23] |
[23:27] |
|---|---|---|---|
| CC / CV / CR / CP | Runtime (int32, s) |
Temperature (float32, °C) |
Setpoint (float32) |
| CAP | Runtime (int32, s) |
Energy (float32, mWh) |
Capacity (float32, mAh) |
| DCR | I1 (float32, A) |
I2 (float32, A) |
Resistance (float32, mΩ) |
| ADV [L] / ADV [S] / POW [A] / POW [DT] | unused | unused | unused |
Derived values shown in the UI:
- Power is computed as
voltage * current - CAP / DCR reuse the setpoint info row to show energy/capacity or I1/I2/R respectively
- Mode label is resolved from the mode byte via
MODE_NAMES - Setpoint unit and precision depend on the active EL15 mode
Warning
This project is still in an early reverse-engineering stage. DM40 scale and range coverage is incomplete, and unknown packet variants can still surface as missing flag support.
Note
If the app crashes with a DM40 KeyError during parsing, that usually means a scale or range flag has not been mapped yet. Please report it with the raw packet if possible.
Note
This project is not affiliated with, endorsed by, or associated with Alientek or any of its subsidiaries.
Licensed under LICENSE.