Skip to content

[digitakt-euclidean] its working fine but when i turn it on, i cant go to any other settings (trig, src, filter, amp) its kinda of stuck in eucledean #662

Closed

Description

@repeat98

Reported on Modwerk for digitakt-euclidean by member_d2c019b04a7a · @sumedho

Device mk1 · OS 1.54
Module version 1.1.4
Firmware Running a Modwerk build
Build fingerprint Not recorded

Configuration

  • digimatrix 1.0.1
  • euclidean 1.1.4
  • note-accumulator 1.1.1
  • ram-machines 1.3.1

Actual

its working fine but when i turn it on, i cant go to any other settings (trig, src, filter, amp) its kinda of stuck in eucledean


Everything the reporter submitted is in this issue. Comments and status changes here are sent to the reporter on Modwerk, and the reporter’s replies appear here.

Module maintainer actions

Reply here normally. Registered authors and verified current maintainers can manage reports with new comments; no fork or repository write access is needed:

  • /modwerk needs-info <question>
  • /modwerk confirm <affected-version|unknown> <reproduction evidence>
  • /modwerk close insufficient_information <explanation>
  • /modwerk close configuration|duplicate|not_reproducible|withdrawn <explanation>
  • /modwerk reopen <explanation>
  • /modwerk resolve <published-version> verified-download

Keep a report open with needs-info while waiting for the reporter. Confirm only a reproduced bug; use unknown for a configuration report. Questions and suggestions can use /modwerk classify question|feature <explanation>. Advanced states: /modwerk investigate <explanation>, /modwerk awaiting-verification <explanation>, /modwerk unconfirm <explanation>.

Only the registered release author can use resolve, after verifying that exact published download fixes the report on their unit. Ordinary closures claim no new firmware fix.

A merged PR alone does not resolve a report. Author release steps.

Activity

  1. sumedho commented on Oct 16, 2026

    @sumedho
    Contributor

    confirm 1.1.4 Reproduced in the emulator and hardware on OS 1.53: with Euclidean open (long FUNC+AMP), TRIG/SRC/FLTR/AMP/LFO were passed to a generic handler and never reached the parameter page; only NO closed it. A fix (1.1.5) closes Euclidean and opens the pressed page; it passes a new regression on 1.53 and 1.54 and is being hardware-tested.

  2. sumedho commented on Oct 16, 2026

    @sumedho
    Contributor

    /modwerk confirm 1.1.4 Reproduced in the emulator on OS 1.53 and 1.54: with Euclidean open (long FUNC + AMP), TRIG, SRC, FLTR, AMP and LFO were passed to a generic handler and never reached the parameter page, so only NO left it. FUNC + FLTR and FUNC + LFO also changed the header underneath while Euclidean stayed on screen. A fix (1.1.5) closes Euclidean and opens the pressed page; it passes a new regression on both OSes and was tested on hardware by the author. It is in review in #675.

  3. repeat98 commented on Oct 19, 2026

    @repeat98
    OwnerAuthor

    Closing as fixed in Euclidean Sequencing 1.1.5, published on Modwerk today (#675). With Euclidean open, TRIG, SRC, FLTR, AMP and LFO now leave it for that page, and FUNC + those keys open Quantize, Delay, Reverb or Compressor as usual. sumedho tested it on a Digitakt with OS 1.53 and 1.54, alone and with all six mods, including save/reload and a power cycle.

    Rebuild your firmware on Modwerk so it includes Euclidean 1.1.5 and flash it. If a page key still doesn't leave Euclidean, reply here and we'll reopen.


    Generated by Claude Code