Skip to content

Repository files navigation

Pool Controller

This project utilizes the Hayward AquaLogic/ProLogic RS485 communication bus to read the frames sent across and then will allow for manipulation of the pool equipment. This saved me upwards of $4,500 so I don't have to use the OmniLogic upgrade system.

image

Components

Elfin EW11 RS485-Wifi module - http://www.hi-flying.com/elfin-ew10-elfin-ew11 image

AquaLogic Board Screenshot 2025-02-04 at 10 26 26 PM

Screenshot 2025-02-04 at 10 27 01 PM

Note: Check documentation for your version of the EW11 as it might not be the same as the ones above.

EW11 Script Script

IOTService Program - To edit the EW11 - SLOW download

Configuration Setup

  • Install the IoTService app on a Windows PC with WiFi access

  • Connect PC WiFi to the EW11 WiFi SSID: EW11_???? (open)

  • Run IOTService app, the device should be found automatically

    • If no device is shown, then the EW11 is not connected to WiFi
    • The default IP address when in AP mode is: 10.10.100.254
    • Connection can also be made with web browser
  • Double click device or single click Config, then click Edit on the Device Status window

image

image

image

  • Setup UART/Socket/WiFI sections as shown above
  • Change WiFI mode to “STA”
  • Enter your own local WiFi SSID and Key in the STA entry
  • Optional, change DNS server under System
  • Confirm Settings and determine new EW11 IP address from IOTService
  • Use Export to save a copy of all the settings in case the EW11 settings get wiped. Import will reload all settings.

Script Load

  • Connect PC to local area network
  • Run IOTService app, the device should be found automatically
  • Double click device, then click Edit
  • Click on Detail
  • IMPORTANT: Set Gap Time to 10 under UART
  • Click on Edit Script
  • Click on Import Script
  • Download the script (docs/EW11.txt):
  • Select Script, then Confirm

image

image

Watch this video of the hardware setup

Special thanks to @swilson and @mas985 for their fantastic research and code they've made available.